This special design provides easier reading when the standard design makes dial reading difficult. The measuring head is rotated by 90º for this purpose.
Note: This model does not include a material thickness compensator
Model | Ranges | Measuring Head Width X* approx. mm | Measuring Head Length Y approx. mm | SCHMIDT Calibration Material** | |
DXV-50 | 10-50 | 38 | 38 | PA: 0.12 mm Ø | |
DXV-120 | 20-120 | 38 | 38 | PA: 0.12 mm Ø | |
DXV-200 | 20-200 | 38 | 38 | PA: 0.12 mm Ø | |
DXV-400 | 20-400 | 38 | 38 | PA: 0.20 mm Ø | |
DXV-1000 | 50-1000 | 40 | 38 | PA: 0.30 mm Ø | |
DXV-1500 | 150-1500 | 40 | 38 | PA: 0.30 mm Ø | |
DXV-2000 | 200-2000 | 40 | 38 | PA: 0.50 mm Ø | |
Other tension ranges available on request. Other units of measure available, such as g. * Width of bracket assembly ** Suitable for 95% of applications - PA = Polyamide Monofilament Special calibration using customer supplied samples is recommended, if process material differs significantly from the SCHMIDT calibration material in diameter, rigidity or shape. For this purpose a material sample of about 5 m should be supplied. |
Calibration: | According to SCHMIDT factory procedure |
Accuracy: | ±1% full scale or ±1 graduation on scale |
Scale diameter: | 41 mm |
Temperature range: | 10-45ºC |
Air humidity: | 85% RH, max. |
Housing material: | Die-cast aluminum |
Housing dimensions: | 188 x 85 x 45 mm (L x W x H) |
Weight, net (gross): | approx. 470 g (1000 g) |